Sign In | Join Free | My bushorchimp.com |
|
Brand Name : Parker
Model Number : N35461091
Certification : cc
Place of Origin : America
MOQ : 1
Price : RMB/100-10000/PC
Payment Terms : T/T
Supply Ability : 10PCS/days
Delivery Time : 3 work days
Packaging Details : wooden case/carton
Core Tube : Stainless steel
Max Temperature : 80°C
Media : Oil
Max Flow : 4
Application : Industrial automation/Process control systems
Response Time : Less than 5ms
Voltage : 12V/24V/110V/220V
Type : Proportional
Product Description:
1. Advantages and Features
High precision and fast response
Using proportional solenoid and high-precision position feedback system (such as D41FH series), the steady-state error can be controlled within ±0.5%, supporting precise flow regulation and dynamic position monitoring;
Millisecond response time, suitable for high-frequency action scenarios (such as automated production lines), and low hysteresis design to improve process repeatability.
Modular and compatible design
Compliant with ISO 5599-2 standard interface, supports quick plug-in installation (such as KA series directional valve), simplifies system integration and maintenance;
Multiple drive modes are optional (electromagnetic, hydraulic, pneumatic), suitable for complex working conditions, such as dual valve core actuators to control multi-action equipment.
Durability and safety protection
Hardened stainless steel plunger and hardened alloy valve core, wear-resistant and corrosion-resistant, significantly extended service life (such as D41F series);
P33 safety exhaust valve supports EN ISO 13849-1 standard, dual-channel redundant design and solid-state pressure sensor, zero delay in fault monitoring, and rapid discharge of residual energy during emergency shutdown.
Multi-function and energy-saving features
Integrated protection functions such as main overflow valve and hydraulic control check valve, support flow priority adjustment and closed center position design to reduce energy loss;
Soft start function can smooth pressure loading, reduce equipment impact and extend system life.
2. Precautions for use
Installation and commissioning specifications
It needs to be installed vertically or horizontally to ensure that the interface direction is consistent with the medium flow direction, and the flange bolts are tightened symmetrically to avoid eccentric load;
Before the first start, it is necessary to fully exhaust and gradually pressurize and debug (the recommended initial pressure is 20%~30% of the rated value) to prevent the seal from being damaged by instantaneous high pressure.
Medium and environmental requirements
The cleanliness of the hydraulic oil must meet the NAS 1638 level 6 standard. Medium containing particles or high viscosity media can easily cause the valve core to jam, and the filter element needs to be cleaned regularly;
The operating temperature range is -10~80℃. In high temperature environments, a heat dissipation device must be configured or a high temperature resistant coil (such as a fluororubber seal model) must be selected.
Operation and load limit
It is forbidden to operate over the rated pressure (such as the maximum continuous pressure of D41FH series is 25MPa). Long-term overload may cause valve body deformation or gear breakage;
Avoid frequent start and stop and sudden load changes to prevent impact loads from affecting the positioning accuracy of the valve core.
Maintenance and parts replacement
Check the status of the seals every 500 hours. When replacing, use original parts (such as propylene rubber seals) to ensure compatibility;
Before long-term shutdown, the residual medium in the system must be emptied and anti-rust oil must be injected to protect internal components (such as plungers and bearings).
Key tips:
Multi-valve linkage requires PLC calibration of synchronization parameters to avoid system conflicts caused by action delays;
Before disassembly and maintenance, the pressure must be released and the power supply must be disconnected to prevent accidents caused by residual energy.
Power Consumption | 2 Watts |
Size | Various sizes available |
Medium | Oil water air |
Pilot Pressure | 1.5-16 |
Supply Voltage | DC24v |
Pilot Flow | 1 |
Valve Size | 1/4 inch |
Core Tube | Stainless steel |
Max Temperature | 80°C |
Media | Oil |
FAQ
Q1: Wonder if you accept small orders?
A1: Do not worry. Feel free to contact us .in order to get more orders and give our clients more convener ,we accept small order.
Q2: Can you send products to my country?
A2: Sure, we can. If you do not have your own ship forwarder, we can help you.
Q3: What's your payment terms ?
A3: By T/T,LC AT SIGHT,100% full payment.
Q4: How long is your production lead time?
A4:It depends on product and order qty. Normally, it takes us 15 days for an order with MOQ qty.
Q5: When can I get the quotation ?
A5: We usually quote you within 24 hours after we get your inquiry. If you are very urgent to get the quotation.Please call us or tell us in your mail, so that we could regard your inquiry priority.
![]() |
Parker N35461091 Pilot Air Control Valve High Precision High Safety New Images |